Weight scale radwag hx7.4p2.6000.h2
Maximum capacity [Max]6000 kg
Minimum load40 kg
Readability [d]2 kg
Tare range-6000 kg
Verification scale interval2 kg
Reading unit2 kg
OIML ClassIII
Display7” graphic colour
Protection classIP 68 construction, IP 66/68 indicator
USB Interface1× standard, 1× option
ETHERNET Interface1× standard
RS232 Interface1× standard, 1× option
1× option
IN/OUT Interface4 IN 4 OUT standard, 12 IN 12 OUT option
Analog output module (option)4-20mA, 0-10V
Power supply100 ÷ 240 V AC 50 / 60 Hz
Power consumption max.25 W
Optional power supply12-24V DC
Operating temperature-10 ÷ +40 °C
Storage temperature-10 ÷ +50 °C
Atmospheric humidity10% ÷ 80% RH no condensation
IndicatorPUE HX7
Keypadmembrane
Number of buttons22
ConstructionStal stainless steel AISI304
Weighing pan dimensions2 pcs 2.5 m
Packaging dimensions2700×400×670 mm
Net weight141.7 kg
Gross weight170.3 kg
Max number of platforms2