Conditioner cards for EDX-100A EDX-200A and EDX-5000A. EDX-5000A does not support CAN card CAN-41A.
Our team will contact you with a quotation within 24 hours.
The cards are for measuring strain, voltage, acceleration, and temperature. CAN data is supported. Isolated amplifier cards and carrier-wave amplifier cards also available for countermeasure against noise.
Specifications
Applicable Recorders
EDX-100A
EDX-200A
EDX-5000A
Channels
8
Measuring Targets
[Strain measurement]
Strain gages, strain-gage transducers
* For strain measurement, use bridge boxes
[Voltage measurement]
Voltage
Voltage-output sensors
[Acceleration measurement (Piezoelectric)]
Piezoelectric accelerometers (Built-in amplifier)
Input Modes
[Strain measurement]
Balanced differential input
[Voltage measurement]
Balanced differential input
*When using the Conversion Adapter FV-1A, this becomes unbalanced input
*Common mode input voltage range ±20 VDC, absolute input voltage range ±50 V
[Acceleration measurement (Piezoelectric)]
Unbalanced input
*Conversion Adapter FV-1A usage possible
Input Impedance
[Strain Measurement]
-
[Voltage measurement]
1 MΩ + 1 MΩ
Within ±10%
*When using Conversion Adapter FV-1A (At unbalanced input), within 1 MΩ ±10%
[Acceleration measurement (Piezoelectric)]
ー
Bridge Excitation or Power Supply to Sensors
[Strain measurement]
Const. voltage output
BV2V: 2 VDC
BV5V: 5 VDC
BV10V: 10 VDC
[Voltage measurement]
Const. voltage output
BV2V: 2 VDC (±1 V)
BV5V: 5 VDC (±2.5 V)
BV10V: 10 VDC (±5 V) or OFF
20 mA/channels or less
[Acceleration measurement (Piezoelectric)]
Const. current output (Approx. 4 mA)
(Excitation voltage: Approx. 23 VDC, Load: 1 kΩ or less)
*Each channel settable.
The max. channels of CVM-41A in EDX-100A is 3 times of units of CVM
Gage Factor
[Strain measurement]
2.00 fixed
[Voltage measurement]
-
[Acceleration measurement (Piezoelectric)]
-
Compatible Bridge Resistance
[Strain measurement]
BV2V: 120 to 1000 Ω
BV5V: 350 to 1000 Ω
BV10V: 500 to 1000 Ω
[Voltage measurement]
-
[Acceleration measurement (Piezoelectric)]
-
Balance Operation Settings(Zero suppression)
[Strain measurement]
-------Autobalance enabled
Cancel the unbalanced bridge portion in the analog circuit, and zero the measurement value.
-------Autobalance disabled
Do not cancel the unbalanced bridge portion
(The initial unbalanced value in the bridge circuit can be confirmed)
[Voltage measurement]
-------Zero suppression enabled
Cancel the input voltage in the analog circuit, and zero the measurement value
-------Zero suppression disabled
Do not cancel the input voltage in the analog circuit
(Display the input voltage as is)
[Acceleration measurement (Piezoelectric)]
-
Balance Adjustment Range
[Strain measurement]
BV2V: Resistance ±10% (±50k ×10-6 strain)
BV5V: Resistance ±4% (±20k ×10-6 strain)
BV10V: Resistance ±2% (±10k ×10-6 strain)
[Voltage measurement]
±5 V
[Acceleration measurement (Piezoelectric)]
-
Measuring Range
[Strain measurement]
BV2V: 5 k, 10 k, 20 k, 50 k, 100 k, 200 k, 500 k ×10-6 strain
BV5V: 5 k, 10 k, 20 k, 50 k, 100 k, 200 k ×10-6 strain
BV10V: 2 k, 5 k, 10 k, 20 k, 50 k, 100 k ×10-6 strain
[Voltage measurement]
1, 2, 5, 10, 20, and 50 V
[Acceleration measurement (Piezoelectric)]
100, 200, 500, 1000, 2000, and 5000 mV
Range Accuracy
[Strain measurement]
Within ±0.2%FS
[Voltage measurement]
Within ±0.2%FS
[Acceleration measurement (Piezoelectric)]
Within ±1.0%FS
Nonlinearity
[Strain measurement]
Within ±0.1%FS
[Voltage measurement]
Within ±0.1%FS
[Acceleration measurement (Piezoelectric)]
Within ±0.2%FS
Calibration (CAL)SHUNT CAL
[Strain measurement]
±100% and ±50% of each range and SHUNT
*When SHUNT CAL has 350 Ω load connected, approx. 257 ×10-6 strain output.
[Voltage measurement]
±100% and ±50% of each range
[Acceleration measurement (Piezoelectric)]
±100% and ±50% of each range
Frequency Response
[Strain measurement]
DC coupling: DC to 5 kHz, deviation +1dB, -3dB
AC coupling: 0.2, 1 Hz to 5 kHz (See the HPF.)
[Voltage measurement]
DC coupling: DC to 5 kHz, deviation +1dB, -3dB
AC coupling: 0.2, 1 Hz to 5 kHz (See the HPF.)
[Acceleration measurement (Piezoelectric)]
0.5 Hz to 5 kHz, deviation +1dB, -3dB
LPF
Transfer characteristics : 5 Butterworth type
Cutoff frequencies : 30, 100, 300, 1 k, 3 k Hz, FLAT and AUTO
*With AUTO settings, the cutoff frequency is set to 1/4 of the sampling frequency.
Cutoff accuracy : Within -3 ±1 dB
Attenuation : -30 (+3, -7) dB /oct.
HPF
[Strain measurement]
Cutoff frequencies: 0.2 Hz, 1 Hz
Attenuation: -6 dB/oct.
[Voltage measurement]
Cutoff frequencies: 0.2 Hz, 1 Hz
Attenuation: -6 dB/oct.
[Acceleration measurement (Piezoelectric)]
-
Resolution
24 bits
*When installed in EDX-100A, its resolution becomes 16 bits.
Distortion Rate
[Strain measurement]
-
[Voltage measurement]
-
[Acceleration measurement (Piezoelectric)]
1% or less
Monitor Output
Accuracy: Within ±5 V ±0.5% (With ±FS)
Nonlinearity: Within ±0.5%FS
Dimensions
22 W x 119 H x 213 D mm (Excluding protrusions)
Weight
Approx. 400 g
TEDS
Reads information from TEDS-installed sensors.
Compliance
Directive 2014/30/EU (EMC)
Directive 2011/65/EU, (EU) 2015/863 (10 restricted substances) (RoHS)
Standard Accessories
2 cross recessed binding head screw M3x6
Optional Accessories
CCA input cable U-111
CVM input cable U-121 to U-123
CVM input integrated cable N-121
Integrated output cable U-62
Conversion adapter FV-1A
Voltage input box VI-8A (-T)
Bridge box for quarter bridge system
DBS-120B-8 (C) (T)
DBS-350B-8 (C) (T)
One-touch type bridge box
DBV-120A-8 (C)
DBV-350A-8 (C)